Anasayfa arrow LED arrow Electroluminescent Wire arrow Connection scheme of electroluminescent wire
Connection scheme of electroluminescent wire

Connection scheme of electroluminescent wire

Инвертор
Инвертор
Diameter of wire – 2,5mm; 5mm. It is connected through power units to a 220V
Инвертор
Инвертор
Инвертор
Инвертор
(standard input tension – 220V/50Hz, output tension – 110V/400Hz), to them are added wires with sockets, shrink tubes with adhesive layer. Consumes a minimum quantity of the electric power (from 0,5 up to 1,2W/sq.m.). Connection directly, without a network power unit, is forbidden! It is forbidden to use other power supplies, except for the inverter applied with a wire with a pressure on an input 12±1,5V.

It is forbidden to use at installation the cords, damaging a surface of wire (also nails, screws, paper clips, etc.).

Therm of services of a wire is 10.000 hours. At use of a blinking mode of luminescence (2/1 sec.) service life increases till 30.000 hours. The guarantee of the manufacturer at correct connection is 1 year. The wire is delivered by roll on 50m.

Схема подключения холодного неона


Схема подключения холодного неона
Contact from a power unit are cleaned in the usual image. Contacts of a wire are cleaned in the following mode:
  1. Caution!!! Remove an external layer of isolation (1) more thin environment.
    ATTENTION! At removal of the second layer of PVC, no cut 2 thin contact wires (7) which are being directly on a layer of luminofore. After removal of a thin layer of PVC of 2 contact wires it is necessary to raise simply.
  2. Extend wires (7) and braid them together.
  3. Release from isolation and luminofore (2) central wire (3).
  4. Remove isolation from both wires (4 and 5) wires of a power unit (10) on 4 - 5 mm.
  5. Dress thin shrink tube (6) on places of prospective connections (8 and 9) and shrink tube of greater diameter on a wire of a power unit (10).
  6. Solder a wire (5) to a wire (7). Solder a wire (4) to a wire (3).
  7. Atop of places of soldering dress shrink tube (6) and, by means of a high-temperature hair drier or an ordinary lighter, carry out shrink tube. Atop dress shrink tube a tube of greater diameter (11) and also carry out shrink.
  8. Other end of an electroluminescent wire also is recommended make hermetic shrink tube to exclude accumulation of a moisture in luminofore layer.. 

Схема подключения холодного неона
Схема подключения холодного неона
Удалите изоляцию с обеих жил (4 и 5) провода блока питания (10) на 4 - 5 мм
Удалите изоляцию с обеих жил (4 и 5) провода блока питания и люминофора
Контакт от блока питания
Припаяйте провод (5) к проводу (7). Припаяйте провод (4) к проводу (3)

Оденьте тонкую термоусадочную трубку (6) на места предполагаемых соединений
Оденьте тонкую термоусадочную трубку (6) на места предполагаемых соединений
Конец электролюминесцентного провода рекомендуется герметизировать термоусадочной трубкой
Конец электролюминесцентного провода рекомендуется герметизировать термоусадочной трубкой


 

ATTENTION! Connect at first the inverter to a neon. And only then attach the inverter to power supplies. Otherwise the inverter will burn down.
 